Screens

Operations

Hear about the fault before the venue does.

Every screen keeps an outbound connection, so the venue firewall stays closed. If that connection drops, the player polls over HTTPS every 60 seconds. The console shows an offline screen as offline — playing from cache, with the manifest version and the date that manifest is valid until.

Network

  • On airSCR-014 · Reception · P-FULL
  • WarningSCR-008 · Storage 86%
  • Offline — playing from cacheSCR-021 · Manifest valid for 6 days

What each screen reports

Online

A heartbeat every 30 seconds. Alert if it is offline more than 10 minutes during opening hours.

Now playing

With every heartbeat. Alert if the same item is stuck for more than 60 seconds.

Screenshot

On demand, and every 15 minutes. Alert if the picture is black, or unchanged over three captures.

Panel

Whether the panel is on, with every heartbeat. Alert if it is off during opening hours.

Hardware

Storage, memory and temperature every 5 minutes. Alert above 85% storage, or above the box’s temperature limit.

Network

Type, Wi-Fi signal and a daily speed test. Alert below a weak signal, or below 5 Mbps.

Cache

On every manifest change. Alert if an asset is missing or fails its hash check.

Clock

Hourly. Alert if it is more than 5 seconds out.

Crashes

As they happen, including watchdog restarts. Alert at two or more in an hour.

Version

App and Android version with every heartbeat. Alert if it is off the approved build.

One diagnose button.

One button per screen runs a checklist — power, panel, network, app, content, clock — and returns a plain-English result.

Diagnose · SCR-008 Panel is off. The HDMI source may have changed. Try: send panel-on command.

A fix runs before the page.

Stuck playback restarts the app. A missing asset downloads again. A crash loop enters safe mode. If the fault remains, operations are alerted by email and SMS, with the diagnosis attached.

Each screen and venue has a health score, an uptime percentage and an incident history. A map shows every venue coloured by status. A sticker on the screen carries its ID and a QR code to a public status page, so venue staff can report a fault in one tap.

Remote actions, by role

Refresh content, clear the cache, restart the app, reboot, panel on or off, volume, rotate the output, take a screenshot, pull logs, run a network test, update or roll back the player, change Wi-Fi, and factory reset. Factory reset is limited to an admin and confirmed twice.

A Wi-Fi change is applied provisionally. If the player cannot reach the server within two minutes, it returns to the previous network on its own. Engineers can open a live view of the box. Every session is logged with the engineer, the screen, and the start and end time.